Link copied. Share now!

DCC50S 12V 50A DC-DC On-Board Battery Charger with MPPT(New Version)

w/ Free BT2 ( valued £39)
Choose your option
Cancel
Confirm
×
Quantity: 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
£299.99
£209.99
x1

DCC50S 12V 50A DC-DC On-Board Battery Charger with MPPT(New Version)

SKU: RBC50D1S-BT-UK
Write a Review
£299.99
£209.99
SAVE £90.00
30%OFF
+ 2090   Renogy Rays after purchase.
  Learn more
  • · Enhanced heat dissipation and safety.
  • · Maximum solar panel input voltage has been upgraded to 50V.
  • · Versatile connections for DIY solar panel setups.
  • · Optimized charging logic for a significant efficiency boost.
  • · Control charging via the DC Home app.
View More
DCC50S 12V 50A DC-DC On-Board Battery Charger with MPPT
DCC50S 12V 50A DC-DC On-Board Battery Charger with MPPT(New Version)
£299.99
£209.99
£299.99
£209.99
Add to cart
Adding to cart… The item has been added
Shop alone
Start group buy
Option
Options: w/ Free BT2 ( valued £39)
DCC50S 12V 50A DC-DC On-Board Battery Charger with MPPT
Want to purchase in bulk? Request Bulk Purchase Prices

Return & refund policy
12V 50A DC-DC On-Board Battery Charger with MPPT
Renogy's enhanced DC-DC Dual Input Battery Charger now supports up to 50V solar input, enabling faster and more efficient house battery charging.
Intelligent Charging Mode Switching
Charge with advanced logic and 'Low Solar Cutoff Mode' for optimal performance in all weather conditions.
Versatile DIY Options
Enjoy greater customization with support for connecting solar modules in series, accommodating up to 50V solar input voltage, and expanding your DIY possibilities.
Adapt to Extreme Temperatures
Consistent high efficiency in extreme temperatures with precise battery temperature compensation.
NEG-terminal design for Easy Installation
The all-in-one NEG-terminal design consolidates connections for the solar panel array, starter battery, and house battery, optimizing installation space and simplifying setup.
Comprehensive System Protections
This battery charger offers advanced intelligent protections for batteries, solar panels, and the alternator, delivering a secure and efficient charging experience while safeguarding your system components.
Soft Start Circuit Design for Enhanced Battery Stability
The soft start circuit gradually increases the charger's input voltage, preventing sudden overvoltage and over-discharge.
Protect Your Solar Panels at Night
Reverse current protection prevents potential damage caused by reverse charging from the battery to the solar panels at night, ensuring system safety and reliable performance.
Package Includes
Only Battery Charger
12V 50A DC-DC On-Board Battery Charger with MPPT
x 1
Battery Temperature Sensor
x 1
Battery Voltage Sensor
x 1
IGN Signal Wire
x 1
User Manual
x 1
with Bluetooth
12V 50A DC-DC On-Board Battery Charger with MPPT
x 1
BT-2 Bluetooth Module
x 1
Battery Temperature Sensor
x 1
Battery Voltage Sensor
x 1
IGN Signal Wire
x 1
User Manual
x 1
with Monitor Screen
12V 50A DC-DC On-Board Battery Charger with MPPT
x 1
Monitoring Screen for DC-DC MPPT Battery Charger Series
x 1
Battery Temperature Sensor
x 1
Battery Voltage Sensor
x 1
IGN Signal Wire
x 1
User Manual
x 1
with Renogy One Core
12V 50A DC-DC On-Board Battery Charger with MPPT
x 1
Renogy ONE Core
x 1
BT-2 Bluetooth Module
x 1
Battery Temperature Sensor
x 1
Battery Voltage Sensor
x 1
IGN Signal Wire
x 1
User Manual
x 1
DCC50S 12V 50A DC-DC On-Board Battery Charger with MPPT
ELECTRICAL DATA
System Voltage
12V-12V
Input Voltage
50 VDC
Output Voltage
9-16 VDC
Alternator Input
Traditional Alternator: 13.2-16 VDC
Smart Alternator (Euro 6): 12-16 VDC
Maximum Output Current Rating
50A
Output Power
660W
Battery Types
AGM/SLD , GEL ,FLD ,LI,USER
Input Fuse Rating
75A-100A
Output Fuse Rating
75A-100A
Charging Efficiency
94%
Temperature Compensation
'-3mV / ℃ / 2V (Non-Lithium)
'0mV / ℃ / 2V (Lithium)
Idle Power Consumption
<30mA
GENERAL DATA
Model
RBC50D1S
Terminal Size
M8 x 1.25 - 10mm
Terminal Range
8AWG-4AWG
Grounding
Common Ground
Communication Protocol
RS485
Operating Temperature Range
'-31℉ to 149℉/-35℃ to 65℃
Storage Temperature Range
'-40℉ to 176℉/-40℃ to 80℃
Humidity
0%-95%, No Condensation
Maximum Operating Altitude
N/A
Enclosure Rating
N/A
Dimensions
9.61 x 5.75 x 3.78 inch/244 x 146 x 96mm
Weight
4.10 lb / 1.86 kg
Certification
CE;ROHS;FCC Part 15 class B; ETL listed to UL 1741 & CSA C22.2
Warranty
2-year material warranty
Protection
Reverse Polarity Protection/Overvoltage Protection/Over Discharge Protection/Overcurrent Protection/Over Temperature Protection/Overcurrent Protection
Frequently Asked Questions
What should be noted when connecting the 50A DC-DC charger to solar panels?
The maximum solar panel input voltage for the 50A DC-DC charger is 50V, and the maximum input power is 660W. Therefore, ensure that the maximum power of the solar panels you connect does not exceed 660W, and the maximum voltage of series or parallel connections does not exceed 50V.
The upgraded version includes a Solar Adapter Cable. Remember to use this accessory to complete the connection between the solar panel and the charger after connecting a single solar panel.
How do I disable the "Solar Low Current Shutdown" mode on the 50A DC-DC charger?
The product comes with an automatic "Solar Low Power" shutdown feature for solar power. If you want to disable this feature during use, you can purchase the BT2 Bluetooth module. After connecting it with DC HOME/RENOGY ONE, you can disable this feature through the terminal device.
What size generator is needed to work with the 50A DC-DC charger?
The charger is connected between the vehicle's main battery and the auxiliary (house) battery. The main battery primarily gets its power from the generator. To ensure efficient charging, the input energy from the main battery side must be sufficient. Therefore, the generator specifications for charging the main battery should be at least 1.5-2 times the charging current of the charger, meaning the generator should be rated at 75A-100A.
Resources Download
Specification
Manual Book
Warranty

17 Reviews